2
Set the value if necessary.
CLI config interface
shelf/slot/port
wavekey in | out
frequency
power value
WEBUI If the Expected Power field is set to Off, select On and click Set Power.
...................................................................................................................................................................................................
3
Perform the procedure “Path Power Trace” (p. 3-8) to identify the network path the
particular alarmed channel is traversing.
...................................................................................................................................................................................................
4
Determine if there is a NE where an OCHCOLLISION-OUT condition is present.
CLI alm
show condition
WEBUI Reports > Alarm List > Total
Reports
> Condition List
...................................................................................................................................................................................................
5
Resolve the OCHCOLLISION-OUT alarm if present by following the steps in the
procedure, “OCHCOLLISION-OUT” (p. 2-211). If this does not correct the problem,
warm
reset the alarmed card.
CLI show condition
config card
card_type shelf slot reset warm
WEBUI Select Reports > Condition List.
Select the card, click the
Reboot tab, select Cold Reboot >Submit.
...................................................................................................................................................................................................
6
Cold reset the alarmed card.
CLI alm
show condition
config card
card_type shelf slot reset cold