2
If checking the add path topology for clean connections between packs did not resolve the
issue, try triggering an egress adjustment at the LD Line port of the egress line to which
the CWR8 Sig port connects.
...................................................................................................................................................................................................
3
Perform a warm reset of the CWR8 pack.
CLI config card
card type shelf slot
reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
4
Perform a cold reset of the CWR8 pack.
CLI config card
card type shelf slot
reset cold
WEBUI Select the card, click the Reboot tab, select Cold Reboot >Submit.
...................................................................................................................................................................................................
5
Replace the CWR8 pack.
...................................................................................................................................................................................................
6
Check whether the WT powers of the alarmed channels are missing at the LD Line port of
the egress line that the CWR8 Sig port connects to.
If... Then...
the WT powers of the alarmed channels are
missing
determine using the PhM lightpath trace or
other method whether excessive loss exists
between the CWR8 Sig port and the egress
line.
the WT powers of the alarmed channels are
not missing
determine if the fiber is kinked along this path
and fix the problem. If loss is excessive and
the fiber is not kinked try to clean connections
between the CWR8 Sig port and the LD Line
port.
...................................................................................................................................................................................................
7
Perform a warm reset of the egress line LD pack.
...................................................................................................................................................................................................
8
Perform a cold reset of the egress line LD pack.
Trouble-clearing procedures
PWRSUSP
PWRSUSP-CWR8 (Power management suspended)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
2-275