Verify that there is a card in the slot against which the alarm is raised. If no card is
present, insert a card of the provisioned type into the slot. To verify which card type has
been provisioned for the slot:
CLI show slot shelf slot
...................................................................................................................................................................................................
4
If... Then...
a card is present, remove the card and check for damage to the
shelf's backplane pins and to the card's
backplane connector.
damage is found on the shelf's backplane, arrange for repair to the backplane. Do not
attempt to reinsert the card.
damage is found on the card, but not on the
backplane,
send the card for repair. Replace the damaged
card with another one of the same type, into
the same slot.
no damage is found on either the backplane or
the card,
replace the card with another one of the same
type into the same slot. If the Card Missing
alarm clears, send the original card for repair.
...................................................................................................................................................................................................
5
If... Then...
the shelf has a single Equipment Controller replace the Equipment Controller.
the shelf has redundant Equipment Controllers
1. switch activity
2. replace the Equipment Controller that used
to be active (but is now inactive)
3. switch activity back again
...................................................................................................................................................................................................
6
If the REPLUNITMISS alarm does not clear, remove the alarmed card and arrange for
repair to the backplane. Follow the return and repair process to return the damaged card
or shelf to an authorized repair center for replacement.
Trouble-clearing procedures
REPLUNITMISS
REPLUNTMISS (Card Missing)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-282
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
E ND OF STEPS
...................................................................................................................................................................................................