REPLUNITMISSMOD
REPLUNTMISS (Pluggable Module Missing)
The optics module (pluggable module) for the port is missing or the card is not able to
successfully detect the presence of the module. The problem could be with the pluggable
module or the card. Typically, this alarm is raised if the pluggable module is not installed
or not properly seated.
Severity Critical (Minor if protected or inactive)
Service affecting? Yes (No, if protected or inactive)
Applicability 112SA1L, 112SCA1, 112SCX10, 112SX10L, 11STAR1,
11STMM10, 11STGE12, 43SCX4, 43STA1P, 43STX4, 43STX4P,
4DPA2, 4DPA4, AHPHG, AHPLG, ALPHG, ALPFGT, A2325A,
AM2017B, AM2125A, AM2125B, OSCT
Corrective Action
NOTICE
Service-disruption hazard
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure “Reseating a Card” (p. 3-19).
If
there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
If there is no pluggable module in the port where the pluggable module missing condition
is raised, then insert one that is appropriate for that transponder card.
...................................................................................................................................................................................................
2
Perform a warm reset of the card.
CLI config card card type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.