Retrieve which Equipment Controller is active. If the Equipment Controller that is to be
replaced is the active Equipment Controller for this shelf, then switch to the other
Equipment Controller. In the Equipment Tree, select the slot containing the Equipment
Controller.
1. Type
show redundancy to determine which Equipment Controller is active on a
shelf.
2. Type
config redundancy sw shelf number to switch the other Equipment
Controller to active, if necessary.
...................................................................................................................................................................................................
4
Remove any cables that are attached to the Equipment Controller to be removed.
...................................................................................................................................................................................................
5
Remove the Equipment Controller from the slot.
...................................................................................................................................................................................................
6
Insert an Equipment Controller blank into the empty Equipment Controller slot.
...................................................................................................................................................................................................
7
Set to the Equipment Controller to be removed to the administrative state of Down, and
then set the slot to empty by typing the following commands:
1.
config slot shelf_slot state down
2. config slot shelf_slot type empty
Card-Specific Troubleshooting
4DPA4 Signal Rates
If the client port on the 4DPA4 is provisioned to the FE or SDSDI signal type, and the
actual received signal does not match, no alarm is raised.
Supporting procedures
Changing the Equipment Controller Configuration in an NE
Changing an NE From a Redundant to a Nonredundant
Equipment Controller Configuration
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
3-76
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
E ND OF STEPS
...................................................................................................................................................................................................