At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Perform a cold reset of the WTOCM.
CLI config card
card type shelf slot
reset cold
WEBUI Select the card, click the Reboot tab, select Cold Reboot >Submit.
...................................................................................................................................................................................................
2
Replace the WTOCM pack (see “Replacing a Card (General)” (p. 3-22)).
Nonredundant PSS-36 and MT0C Clock Source
In the PSS-36 the clock source is provided by the MT0C pack. If the MT0C pack is
removed from a nonredundant (simplex) PSS-36 system, service will be affected. Do not
remove the MT0C pack in a nonredundant configuration where traffic is present.
Supporting procedures
Card-Specific Troubleshooting
Egress Adjustment Failure and Clock Source (WTOCM and
PF)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
3-79
E ND OF STEPS
...................................................................................................................................................................................................