Publication 1756-RM084F-EN-P - July 2002
Entering Function Block Diagram Logic 5-11
Where:
BLOCK guidelines
If the Operand is not a qualified tag of the correct data type, the
block will not be verified.
Some function block instructions require specific arrays. This
table lists the valid Array Name for each of these instructions:
The X and Y grid locations are a relative position from the
upper-left corner of the sheet. X is the horizontal position; Y is
the vertical position.
Item: Identifies:
ID
the block identifier; uniqueness is important for wiring
enter unsigned, 32-bit integer value
Specify:
ID := ”
number
X
x-coordinates on internal grid
enter unsigned, 32-bit integer value
Specify:
X := ”
number
Y
y-coordinates on internal grid
enter unsigned, 32-bit integer value
Specify:
Y := ”
number
Operand
tag name for the block (optional)
Specify:
Operand := ”
tag_name
ArrayName
tag name for array (optional)
Specify:
ArrayName := ”
array_name
VisiblePins
Comma-separated list of the names of all the parameters
with pins visible for wiring. The names match the
member names of the data type of the block tag.
Specify:
VisiblePins := ”
parameter
Instruction: Array Name:
DEDT Storage (required)
FGEN X1 (required)
Y1 (required)
X2 (optional)
Y2 (optional)
MAVE Storage (required)
Weight (optional)
RMPS RampValue (required)
SoakValue (required)
SoakTime (required)