Rockwell Automation Publication 2080-UM004D-EN-E - March 2018 81
Specifications Appendix A
Certifications – 2080-DNET20
Certification (when product is
marked)
(1)
(1) See the Product Certification link at http://www.rockwellautomation.com/products/certification/ for
Declarations of Conformity, Certificates, and other certification details.
Value
c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada.
See UL File E322657.
UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations,
certified for U.S. and Canada. See UL File E334470.
CE European Union 2014/30/EU EMC Directive, compliant with:
EN 61326-1; Meas./Control/Lab., Industrial Requirements
EN 61000-6-2; Industrial Immunity
EN 61000-6-4; Industrial Emissions
EN 61131-2; Programmable Controllers (Clause 8, Zone A & B)
RCM Australian Radiocommunications Act, compliant with:
AS/NZS CISPR 11; Industrial Emissions
KC Korean Registration of Broadcasting and Communications
Equipment, compliant with:
Article 58-2 of Radio Waves Act, Clause 3
EAC Russian Customs Union TR CU 020/2011 EMC Technical Regulation
DeviceNet ODVA conformance tested to DeviceNet specifications.
General and Environmental Specifications – 2080-SERIALISOL
Attribute Value
Mounting torque 0.2 Nm (1.48 lb-in)
Terminal screw torque 0.22…0.25 Nm (1.95…2.21 lb-in)
(using a 2.5 mm (0.10 in.) flat-blade screwdriver)
Wire size
Isolated voltage 500V AC
Temperature, operating IEC60068-2-1 (Test Ad, Operating Cold),
IEC60068-2-2, (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
-20...65 °C (-4…149 °F)
Temperature, surrounding air,
max.
65 °C (149 °F)
Temperature,
non-operating
IEC60068-2-1 (Test Ad, Operating Cold),
IEC60068-2-2, (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
-40...85 °C (-40…185 °F)
Vibration IEC 60068-2-6 (Test Fc, Operating):
2g @ 10...500 Hz
Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock):
25 g
Min Max
Solid 0.14 mm
2
(26 AWG)
1.5 mm
2
(16 AWG)
rated @ 90 °C
(194 °F )
insulation max
Stranded 0.14 mm
2
(26 AWG)
1.0 mm
2
(18 AWG)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Micro800 2080-MEMBAK-RTC2 and is the answer not in the manual?

Allen-Bradley Micro800 2080-MEMBAK-RTC2 Specifications

General IconGeneral
BrandAllen-Bradley
ModelMicro800 2080-MEMBAK-RTC2
CategoryControl Unit
LanguageEnglish

Related product manuals