Allen-Bradley POINT I/O User Manual

Allen-Bradley POINT I/O
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
POINT I/O and ArmorPOINT I/O 2 Port
EtherNet/IP Adapters
Catalog Numbers 1734-AENTR, 1738-AENTR
User Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley POINT I/O and is the answer not in the manual?

Allen-Bradley POINT I/O Specifications

General IconGeneral
Power Supply24V DC
MountingDIN Rail
Wiring MethodRemovable terminal blocks
Communication ProtocolsEtherNet/IP, DeviceNet, ControlNet
Operating Temperature Range-20°C to 60°C (-4°F to 140°F)
Number of ChannelsVaries by module (e.g., 8, 16, 32)
CertificationsCE, cUL
TypeDigital and Analog I/O Modules
Output Voltage24V DC

Summary

Chapter 1 About the Adapters

Important Adapter Considerations

Notes important considerations before using the adapter and warns about module compatibility.

Set the Chassis Size

Explains the procedure for configuring the chassis size for I/O connections.

Chapter 2 Install Your Adapter

Chapter 3 Configure the Adapter for Your EtherNet/IP Network

Configuration Requirements

Outlines requirements for configuring IP address, subnet mask, and gateway address.

Use the Rockwell BootP/DHCP Utility

Guides on using the BootP/DHCP utility for IP address configuration.

Use DHCP Software to Configure Your Adapter

Warns about using DHCP and recommends fixed IP addresses for stability.

Chapter 4 Configure the Adapter for Direct Connection in RSLogix 5000 Software

Configure the I/O

Details adding modules to the controller's I/O configuration.

Add the POINT I/O Adapter to the I/O Configuration

Describes adding the POINT I/O adapter as a child of the Ethernet bridge.

Add the POINT I/O Modules to the I/O Configuration

Guides adding POINT I/O modules to the configuration list.

Configure the Adapter with Fixed IP Address

Details configuring a fixed IP address to maintain communication.

Chapter 5 Configure the Adapter for Direct Connection and Rack Optimization in RSLogix 5000 Software

Set Up the Hardware

Describes setting up the I/O hardware for a ControlLogix system.

Configure the I/O Modules

Details adding I/O modules to the controller I/O configuration.

Add the Local EtherNet/IP Bridge to the I/O Configuration

Explains adding the EtherNet/IP bridge module to the I/O configuration.

Add the I/O Adapter to the I/O Configuration

Describes adding the I/O adapter as a child of the Ethernet bridge.

Add the POINT I/O Module and Configure for Rack-optimized Connection

Guides adding POINT I/O modules and configuring rack-optimized connections.

Add the POINT I/O Module and Configure For Direct Connection

Guides adding POINT I/O modules and configuring direct connections.

Download the Program to the Controller

Provides steps to download the program to the ControlLogix controller.

Verify the Module Chassis Size

Explains synchronizing chassis size from software to hardware.

Appendix A EtherNet/IP I/O Adapter Specifications

General Specifications – POINT I/O and ArmorPOINT I/O 2 Port EtherNet/IP Adapters 1734-AENTR, 1738-AENTR

Lists general specifications for POINT and ArmorPOINT I/O 2 Port EtherNet/IP Adapters.

Appendix B Adapter Web Dialogs

Appendix C Configure the RSLinx Ethernet Communication Driver

Install the RSLinx Software

Provides instructions for installing the RSLinx software.

Configure the AB_ETH Driver

Details configuring the AB_ETH Ethernet communication driver.

Configure the AB_ETH/IP Driver

Explains how to configure the AB-ETHIP Ethernet communication driver.

Related product manuals