Encoder Usage and Position StepLogic Application F-11
E248 [Enh Control Word]
This parameter allows many of the positioning functions to be completed 
via parameter control using an explicit message. This allows the 
operation over communications instead of with hardware inputs. The bits 
have the same functions as the digital input options of the same name. 
Options relating to positioning are:
Bit 0 “Home Limit”
Bit 1 “Find Home”
Bit 2 “Hold Step”
Bit 3 “Pos Redefine”
E230-E244 [Step Units x]
All of the position steps can be written to while the drive is running. The 
changes will take place at the next move. For example, if step 0 is 
over-written while the drive is moving to step 0, the drive will move to 
the previous commanded position at step 0. The next time the drive is 
commanded to return to step 0 it will proceed to the new position. One 
possible use of this capability is when an application requires full control 
of the movement by a controller external to the drive. The Step Logic 
program might be written to jump from step 0 back to step 0 when Input 
1 is active. The controller could write any desired position to step 0 and 
then toggle the input 1 bit of E248 [Enh Control Word] to cause the drive 
to move to the new position. This allows almost unlimited flexibility and 
can be used with absolute or incremental moves.
Setup Notes
The RA computer tools (DriveExplorer and DriveTools SP) can make 
setup of the positioning functions much easier. Please refer to the latest 
versions for additional tools or wizards which can aid in the setup.