Overview P-3
General Precautions
ATTENTION:  The drive contains high voltage capacitors which take 
time to discharge after removal of mains supply. Before working on 
drive, ensure isolation of mains supply from line inputs [R, S, T (L1, 
L2, L3)]. Wait three minutes for capacitors to discharge to safe voltage 
levels. Failure to do so may result in personal injury or death.
Darkened display LEDs is not an indication that capacitors have 
discharged to safe voltage levels.
ATTENTION:  Only qualified personnel familiar with adjustable 
frequency AC drives and associated machinery should plan or 
implement the installation, start-up and subsequent maintenance of the 
system. Failure to comply may result in personal injury and/or 
equipment damage.
ATTENTION:  This drive contains ESD (Electrostatic Discharge) 
sensitive parts and assemblies. Static control precautions are required 
when installing, testing, servicing or repairing this assembly. 
Component damage may result if ESD control procedures are not 
followed. If you are not familiar with static control procedures, 
reference A-B publication 8000-4.5.2, “Guarding Against Electrostatic 
Damage” or any other applicable ESD protection handbook.
ATTENTION:  An incorrectly applied or installed drive can result in 
component damage or a reduction in product life. Wiring or application 
errors, such as, undersizing the motor, incorrect or inadequate AC 
supply, or excessive ambient temperatures may result in malfunction of 
the system.
ATTENTION:  The bus regulator function is extremely useful for 
preventing nuisance overvoltage faults resulting from aggressive 
decelerations, overhauling loads, and eccentric loads. However, it can 
also cause either of the following two conditions to occur.
1. Fast positive changes in input voltage or imbalanced input voltages 
can cause uncommanded positive speed changes;
2. Actual deceleration times can be longer than commanded 
deceleration times
However, a “Stall Fault” is generated if the drive remains in this state 
for 1 minute. If this condition is unacceptable, the bus regulator must be 
disabled (see parameter A117
). In addition, installing a properly sized 
dynamic brake resistor will provide equal or better performance in most 
cases.
ATTENTION:  Risk of injury or equipment damage exists. Drive does 
not contain user-serviceable components. Do not disassemble drive 
chassis.