© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT11-06-150R8
103
UniLinc PDA Application (Continued)
Enabling/Disabling Cycles
1. From the Maintenance Options menu, press Enable/Disable Cycles. The Communications screen
appears.
2. Aim the PDA at the “Infrared Comm Port” window on the machine’s control. Press OK. The
Enable/Disable Cycles screen appears.
3. To view the cycle information, press the Cycle Info tab. The Cycle Information list appears. To
save the cycle information into a text file, press Create File.
4. To enable/disable a cycle, press the On/Off tab. Press the check box next to the cycle number.
When a check appears in a box, the cycle is enabled. To enable/disable all cycles, press and hold
the screen until the pop-up window appears. Press either Enable All Cycles or Disable All
Cycles.
5. Press Send. The Communications screen appears.
6. Aim the PDA at the “Infrared Comm Port” window on the machine’s control. Press OK.