Specifications
131Alvium G1 User Guide V1.7.0
Power requirements 12 to 24 VDC
Power requirements (PoE) IEEE 802.3af
Power consumption (typical)
External power: 3.8 W at 12 VDC
Power over Ethernet: 4.2 W
Storage temperature -20 °C to +85 °C ambient temperature
Operating temperature
Hardware
option
Housing
3
Cooling area
4
Mainboard
5
G1 BL
No Mount
6
-20 °C to +65 °C -20 °C to +85 °C
-20 °C to +85 °CG1 BL
with mount
7
-20 °C to +65 °C -20 °C to +85 °C
Closed Housing -20 °C to +65 °C Not applicable
Relative humidity 0% to 80% (non-condensing)
Digital interface 1000BASE-T
Camera controls GenICam (GenICam Access)
3
Including the interface assembly for G1 BL models
4
See Heat dissipation for Alvium G1 BL on page 177 and Mounting the G1 BL interface unit on page 184.
5
Output by DeviceTemperature
6
Ensure that the sensor is operated in the temperature range specified by the manufacturer. For any
questions, please visit www.alliedvision.com/en/support.
Housing temperature applies to the interface unit only.
7
Temperature values must be observed for the housing and for the cooling areas.
Feature Specification
Table 58: Alvium G1-2040m/c specifications (sheet 2 of 2)