Installing the camera
182Alvium G1 User Guide V1.7.0
Mounting G1 BL No Mount cameras
1. Disconnect the camera from power.
2. With 2 fingers grabbing the cable side FPC connector (e) at the edges,
disconnect the FPC cable from the FPC connector (f) of the sensor unit as
shown in Figure 58.
Heat dissipation and electromagnetic compatibility for G1 BL No Mount cameras
For heat dissipation, see the Optimum Heat Dissipation for Alvium Cameras
application note.
For initial guidance on electromagnetic compatibility, see the Electromagnetic
Compatibility for Open Housing Alvium Cameras application note.
See www.alliedvision.com/en/support/technical-documentation/
alvium-gige-documentation.
NOTICE
Damage to the camera by short circuits
The connection between the FPC cable and the G1 BL interface unit cannot be
disconnected without disassembling the interface unit. Disassembly and improper
reconnection can damage the camera. For the interface unit,...
...keep the screws untouched and keep the FPC cable connected.
Disconnect the FPC cable only on the sensor unit side as shown
in Figure 58.
Figure 58: Disconnecting the interface unit from the sensor unit