Camera interfaces
201Alvium G1 User Guide V1.7.0
Levels
Minimum pulse width
Test conditions
The input signal was driven with 3.3 V and no external additional series resistor.
Isolated output description
Parameter Value
U
in
(low) 0 to 1.0 V
U
in
(high) 3 to 24 V
Current (constant-current source) 3 to 4 mA
Table 104: Input parameters
Figure 72: Minimum pulse width
Figure 73: Output block diagram
I
F
0
t
ϰϰʅƐ
ϲʅƐ 20 kHz
ExternalInternal
OPT OUT PWR
GPO2
R