Compliance, safety, and intended use
42Alvium G1 User Guide V1.7.0
Heat dissipation with Alvium G1 BL
In addition to the instructions in Providing optimum heat dissipation on page 41,
observe the following:
Design Alvium G1 BL cameras into a heat dissipative housing with a high thermal
conductivity. See also Cooling area for the Alvium G1 BL sensor unit on page 178
and Mounting the G1 BL interface unit on page 184.
Keep the operating temperature in the specified range to enable best image
quality and to protect the camera from damage. Temperature values apply to a
relative humidity of 0 to 80 percent that is non-condensing.
Observe that not only the sensor unit must be cooled, but also the interface unit as
shown in Figure 2.
Hardware option Housing
Components in the
cooling area
1
Mainboard
2
Without mount
3
Not applicable
-20 °C to +85 °C
See model
Specifications on page
58.
With mount
4
-20 °C to +65 °C
1
See Heat dissipation for Alvium G1 BL on page 177.
2
Output by DeviceTemperature, using Direct Register Access.
3
Ensure that the sensor is operated in the temperature range specified by the manufacturer. For any
questions, please visit www.alliedvision.com/en/support.
4
Temperature values must be observed for the housing and for the cooling area.
Table 8: Operating temperature ranges for Alvium G1 BL cameras
Figure 2: Heat dissipation for Alvium G1 BL cameras
More information
For more information on heat dissipation, see the Optimum Heat Dissipation for
Alvium Cameras application note at
www.alliedvision.com/en/support/technical-documentation/
alvium-csi-2-documentation.
Mounting base