Camera interfaces
200Alvium G1 User Guide V1.7.0
I/Os and GPIOs
Isolated input description
The input can be connected directly to the system for voltages up to 24 VDC.
An external resistor is not necessary.
I/O use for UART
Table 103 shows which values must be selected to control I/Os using
LineSelector.
Signal LineSelector (GenICam) UART line
EXT-GPIO 0 Line0 UART Tx
EXT-GPIO 1 Line1 UART Rx
EXT-GPIO 2 Line2 Not applicable
EXT-GPIO 3 Line3 Not applicable
Table 103: Value settings to control I/Os using the LineSelector feature
Feature descriptions and firmware downloads
Alvium Features Reference: www.alliedvision.com/en/support/
technical-documentation/alvium-gige-documentation
Firmware downloads: www.alliedvision.com/en/support/firmware-downloads.
Figure 71: Input block diagram