Camera interfaces
204Alvium G1 User Guide V1.7.0
Input levels
The GPIOs can be connected directly to the system controlling the camera for
voltages up to 5.5 VDC. An external resistor is not necessary.
Output levels
NOTICE
Damage to the camera by high input voltage
Exceeding the maximum input voltage can damage the camera.
Keep maximum input voltage below 5.5 VDC.
Parameter Value
U
in
(low) -0.3 to 0.8 VDC
U
in
(high) 2.0 to 5.5 VDC
Undefined levels 0.8 to 2.0 VDC
Table 107: GPIOs as input, voltage levels
NOTICE
Damage to the camera by high output current
The camera can be damaged when connected to a device that exceeds the specified
maximum current or voltage. Keep the maximum current below 12 mA per output.
Parameter Value
External output voltage U
out
(low, Off state) 0 to 0.4 VDC
External output voltage U
out
(high, On state) 2.4 to 3.3 VDC
Undefined levels 0.4 to 2.4 VDC
Maximum external output voltage 3.3 VDC
Maximum output current 12 mA
Table 108: GPIOs as output, current and voltage levels
Output voltage for U
Out
(high) = On state
The voltage level in the On state depends on the load current. Higher currents yield
lower voltage.