Maintenance
Opus Operator's Manual 7-3
7.5 Fuse Replacement
To replace burnt fuses:
1. Turn off the system and disconnect the power cable from the outlet.
2. Unplug the power cable from the power cable connection port on the
service panel.
3. Remove the fuse housing as shown in Figure 7-3.
4. Remove the burnt fuses from the housing and replace them with the new
ones.
5. Make sure that the fuses fit snugly within the fuse housing.
6. Insert the fuse housing into its receptacle and push it in until it snaps into
place.
7. Connect the power cable to the system and to the mains outlet.
8. Turn on the system and verify that it is functioning properly.
Caution
Make sure that the type and rating of the new and the replaced fuses match.
Always replace both fuses at the same time.
Figure 7-3: Fuse Housing