Chapter VI Specified Function Introduction
100
Function
Code
Parameter Name
Attribute
Setting
Range
Unit
Factory
Defaults
P03.13
Analog input gain
Immediately
effective
0~500
%
100
Function Description:
In the analog speed control mode, it describes the proportional relationship between the
set motor speed command value and rotation command input voltage.
In the torque control mode, it describes the proportional relationship between the set
motor torque command value and torque command input voltage.
When the set value is 100%, the ±10V voltage is corresponding to motor rated speed,
or motor rated torque.
Input Voltage
Speed Command/
Torque Command
After Compensation Curve
Zero Compensation Value
Before Compensation Curve