Chapter VI Specified Function Introduction
94
Function Description:
Setting the delay time from servo-on to holding brake released.
Function
Code
Parameter Name
Attribute
Setting
Range
Unit
Factory
Defaults
P01.16
Brake resistor
external selection
Power up
effective
0~1
-
0
Function Description:
The default value is 0, namely to choose internal braking resistor. Choose external
braking resistor for 1.
Function
Code
Parameter Name
Attribute
Setting
Range
Unit
Factory
Defaults
P01.17
Power of external
brake resistor
Power up
effective
100~10,000
W
Related
to the
capacity
of drive.
Function Description:
There is a standard built-in braking resistor in the drive. See its specification in the
related contents of appendix in this manual. It requires the external braking resistor
when the specification of built-in braking resistor can't meet the requirements of actual
working condition. The parameter should be set at P01.16 =1, then the external braking
would be chosen. The power and resistance value of external resistor should be written
in P01.17 and P01.18 respectively.
Function
Code
Parameter Name
Attribute
Setting
Range
Unit
Factory
Defaults
P01.18
Resistance value of
the external brake
resistor
Power up
effective
12~500
Ω
Related
to the
capacity
of drive.
Function Description:
Refer to P01.17 for description.