hypercharger - Operation Instructions and Installation Guide
Hardware
Version 2-2
All rights reserved. The reproduction of this document, also partially, is allowed only with authorization by alpitronic Srl
2.6. Additional options
2.6.1. Cooling unit
If an active cooled cable is used (see chapter 2.1) a cooling unit for each cooled cable is
needed.
Remark
Only one cooling unit can be installed in the HYC_150, a maximum of two
cooling units are possible in the HYC_300.
Figure 30: Cooling unit for cooled charging cable (optional)
A Connection cooling liquid
B Filler neck
C Fill level indicator
D Cooling fans
To facilitate the electrical installation of the hypercharger, the cooling unit should be removed
during grid connection (see chapter 4.2.4)
Cooling liquid
The only coolant that can be used is ‘innovatek Protect PRO Konzentrat’ by innovatek OS
GmbH. The coolant is delivered in a default concentration of 52 % with an antifreeze
protection reaching -40°C. The filling volume is approx. 1.5 l for cooling unit and charging
cable.
Attention
Note that for proper operation, use only the original intended coolant!
Orders can be sent to sales@hypercharger.it, the coolant is delivered in
1 liter bottles.