Table 1-1
2 kW to 3 kW High Series Technical Characteristics – Continued
PARAMETERS
SPECIFICATIONS
REMOTE PROGRAMMING
Resistive:
Constant Voltage (0-100%)
Constant Current (0-100%)
Voltage:
Constant Voltage (0-100%)
Constant Current (0-100%)
Remote Sensing
ENVIRONMENTAL CHARACTERISTICS
Temperature Coefficient
Ambient Temperature
Operating
Storage
Humidity
Cooling
Agency Approvals (excludes 600 volt
models)
0 - 5k ohms
0 - 5k ohms
0 - 5/10 VDC
0 - 5/10 VDC
Terminals are provided to sense output voltage
at point of load. Maximum line drop
3% of rated voltage per line, or 2 volts,
whichever is less.
0.02%/°C of max. output voltage rating for
voltage set point.
0.03%/°C of max. output current rating for
current set point.
0 to 50°C
-40° to 75°C
0-80% RH, non-condensing
Internal fans
T
ÜV NRTL to UL1950
T
ÜV to IEC 950
CE mark
M550004-01