Table 2-3
Output Connection Descriptions*
SUPPLY TYPE
CONNECTION DESCRIPTION
2kW to 3kW <=60V
6.6kW to 10kW <=60V
13.3kW to 20kW <=60V
2kW to 3kW >=80V
5kW to 15kW >=80V
16kW to 30kW >=80V
Bus Bar with hole for 3/8” bolt
Bus Bar with two holes for 3/8” bolts
Bus Bar with three holes for 3/8” bolts
Terminal Block with 10-32 screws
3/8” Threaded Studs
3/8” Threaded Studs
* Under no condition should the negative output terminal exceed 150 volts, positive or
negative, from chassis potential.
Table 2-4
Input Connection Descriptions
Note: Observe the maximum torque specification indicated on the cover.
INPUT
VOLTS
PHASE
COUNT
P62 NON-
MODULAR
P63, P83, D3
NON-MODULAR
P66, P86
MODULAR
220/230 1-phase 8-32 NA NA
208 3-phase 8-32 ¼ - 20 ¼ - 20
400 3-phase NA 10 - 32 ¼ - 20
480 3-phase NA 10 - 32 ¼ - 20
Table 2-5
Maximum AC Current Ratings
Input Line Current
Input V
3.3 kW 6.6 kW 10 kW 13.3 kW 16.6 kW 20 kW
Unit of
Measure
200-240 VAC 15 29 44 57 72 87
360-440 VAC 10 19 28 37 46 56
480 VAC 9 18 27 35 44 53
Amps AC
per phase