Chapter 4
AUTO-STEP PROGRAMMING
4.1 INTRODUCTION
The DHP series power supplies allow the user to enter a sequence of up to nine steps
into memory for later execution. These steps include settings for voltage, current, OVP,
and time for each step. A simple programming sequence is used. This chapter
describes the use of the auto-step programming feature of the power supply.
4.2 PROGRAMMING
The programming sequence for each of the nine steps is identical. Each programming
sequence requires the input entries:
1. The step number to be programmed
2. The output voltage for the step
3. The output current for the step
4. The OVP setting for the step
5. The time for the step
6. What to do after the step is completed
A diagram showing an overview of the auto-step programming menu system is shown in
figure 4-2 on the following page.
To enter the auto-step programming mode push the MENU key until the auto-step
programming screen shown below in Figure 1 appears.
Figure 4-1
Auto-step Programming Screen
Press enter at this screen to enter the auto-step programming mode.
M550004-01
4-1