Appendix C: Troubleshooting
78
Tango Series Audio Controllers
Source Unit Connections
Problems in source cabling can often be traced to symptoms where the source cannot be heard in any
zone and/or when the source doesn’t seem to respond to keypad commands.
1. Ensure that the source component’s LINE OUT connections are connected to the Controller’s LINE
IN connections for the correct device. These can sometimes be mismatched.
2. Take a look at the source component to ensure that MUTE functions have not accidentally been
activated.
3. Check to see that the IR emitter lead is securely fastened to the IR receiver on the source component
and that you have the lead plugged into the appropriate IR output jack. These can sometimes be
mismatched. When a keypad command is received and communicated to the source device, there is
a LED that lights on the front of the Controller indicating the processing of the command. If the
LED does not light with a keypad press, then it is possible that the device has not been programmed.
If the LED does light, there may be a problem with the IR emitter lead.
When testing IR problems, it is helpful to carry a blinking emitter or a test emitter to ensure that the
commands are being sent to the source. Techniques you can use to help isolate a sources problem
include swapping the source with another on the Controller to see if the problem stays with the
Controller or follows the movement of the source. Also try swapping IR emitter leads.
Zone Connection Problems
If there is wall power and both the source components and the Controller seem to be powering up OK,
but one or more of the zones are not working, there may be a problem at the individual zone or with the
cabling connecting to the zone. Begin by checking each zone keypad for functionality by pressing the
desired source button. The LED should light red next to the source on the KP-4e keypads or should
“wake up” with a screen menu on the touch panel keypad.
Dead Zones
There is power and the source devices and the Tango Controller seem to be powering up OK, but one or
more of the zones are not working.
Check each zones keypad for functionality by pressing the desired source button. The LED should light
Red next to the source.
LED Does Not light
You are not getting power and command connectivity to the zone. Check other zones and select each
source to determine if this is specific to the source or the room in general. If the problem is in a particular
room then there may be an issue with cabling to your speakers or it may be the keypad itself. If you get
similar results for a particular source in multiple zones then there may be an issue with the source
equipment and you should check to see that the selected source is ‘playing’. If every other zone is ok,
check to make sure cables to the speakers are secure and that you have tried to increase the volume level
in the zone.
Possible Causes:
Zone connectors at Tango Controller are not secure.
Connector at Keypad to Tango Controller is not secure.
Wiring standard not followed. Make certain the center two wires are in the same orientation at
the Tango Controller and the keypad. They may have been inadvertently reversed during the
installation.
Input and output connectors on keypad are reversed.
Keypad not recognized by system. Restart system.

Table of Contents

Other manuals for AMX DAS-T0804-SIG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX DAS-T0804-SIG and is the answer not in the manual?

AMX DAS-T0804-SIG Specifications

General IconGeneral
BrandAMX
ModelDAS-T0804-SIG
CategoryRecording Equipment
LanguageEnglish

Related product manuals