Protected Settings Menu
23
Mio Modero R-4 Remote
Checking Connection Status
1.
Select Protected Settings in the Setup Menu.
2. Select System Settings in the Protected Settings Menu. If the round button at the top right of the first page is green,
the system is connected.
3. Select the Back button until you are out of the Setup Menu.
Checking the Master IP Address
1.
Select Protected Settings in the Setup Menu.
2. Select System Settings in the Protected Settings Menu. The master IP is indicated on the first page.
3. Select the Back button until you are out of the Setup Menu.
Checking the Gateway IP Address
1.
Select Protected Settings in the Setup Menu.
2. Select System Settings in the Protected Settings Menu. The gateway IP is indicated on the second page.
3. Select the Back button until you are out of the Setup Menu.
Checking the Gateway EUI Address
1.
Select Protected Settings in the Setup menu.
2. Select System Settings in the Protected Settings Menu.
3. Select the device’s down arrow to navigate to the second page. The Gateway EUI address is indicated on the second
page.
4. Select the Back button until you are out of the Setup Menu.
Checking the Extended PAN ID
1.
Select Protected Settings in the Setup Menu.
2. Select System Settings in the Protected Settings Menu.
3. Select the device’s down arrow to navigate to the second page. The Extended PAN ID is indicated at the bottom of
the page, above the Network Scan and ZigBee Statistics buttons.
4. Select the Back button until you are out of the Setup Menu.
Changing the Device Number
1.
Select Protected Settings in the Setup Menu.
2. Select System Settings in the Protected Settings Menu.
3. The Device Number button at the bottom of the first page lists the current NetLinx Device Number for the unit.
4. To change the device number, press the Device Number button to open the Device Number page.
5. Enter the new device number with the device keypad.
To move the cursor back one number at a time, press the Back button.
To clear the entire device number field, press the Clear button.
To return to the System Settings page without saving any changes, press the Abort button.
To save any changes and return to the System Settings page, press the Done button.
6. Reboot the Mio R-4 from the Reboot Page (see the Reboot Page section on page 26).
System Settings (Cont.)
Device Number The number of the device in the NetLinx system.
Gateway IP The IP for the Gateway providing the connection.
Gateway EUI Address The EUI Address for the Gateway providing the connection.
Device EUI A ZigBee network ID unique to the device.
Extended PANID The ID for the ZigBee personal area network.
Network Scan This button opens the Site Survey page (FIG. 19).
ZigBee Diagnostic This button opens the ZigBee Diagnostics page (FIG. 20).

Table of Contents

Other manuals for AMX MIO-R4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX MIO-R4 and is the answer not in the manual?

AMX MIO-R4 Specifications

General IconGeneral
Flash memory32 MB
RAM capacity64 MB
CertificationFCC, IC, CE, IEC 60950, Japan Approval
Maximum range30 m
Frequency band2.4 GHz
Languages supportARA, CHI (SIMPL), DEU, ENG, ESP, FRE, GRE, HUN, ITA, JPN, KOR, POR, RUS, THA
Number of devices supported2
InterfaceIR Wireless
Input typePress buttons
Hard buttonsYes
Product colorBlack
Buttons quantity29
Remote control proper use-
Display diagonal2.4 \
Display resolution240 x 320 pixels
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 40 °C
Package weight25 g
Weight and Dimensions IconWeight and Dimensions
Depth19 mm
Width51 mm
Height240 mm
Weight20 g