EasyManuals Logo

AMX MVP-9000i User Manual

AMX MVP-9000i
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #109 background imageLoading...
Page #109 background image
Upgrading Firmware
95
MVP-9000i 9" Modero® ViewPoint® Touch Panel with Intercom
Upgrading from Previous Firmware
The MVP-9000i allows the option to revert the device to the previous firmware run before an upgrade. To upgrade the
device from previously loaded firmware:
1. From the Protected Setup page, press the Options button to open the System & Panel Options page.
2. In the System Options section, press the Install Firmware button.
3. In the Firmware Installation popup window (FIG. 71), press the Previous button.
4. The Confirmation Dialog box (FIG. 104) will ask “Are you sure you want to install the following firmware?” The
option to choose Yes will be enabled after five seconds. Press Yes to load the firmware listed, and No to return to the
Firmware Installation popup window.
5. If you choose Yes, the device will retrieve the files and then reboot (FIG. 105).
Upgrading Firmware Via NetLinx Studio
The MVP-9000i uses a 5-pin CC-USB (Type A) to Mini-B 5-Wire programming cable (FG10-5965) for programming,
firmware updates, and touch panel file transfer between a PC and the target device. If a programming cable is not
available, it may be purchased from www.amx.com. The Mini-USB port for the connector is located on the left side of
the device as viewed from the front.
Before beginning with this section, verify that the device is powered and the Type-A end of the USB connector is
inserted and secure in the PC’s USB port. The panel must be powered On before connecting the mini-USB connector
to the panel. To guarantee that the upgrade is not interrupted by power loss, connecting the device to a power source,
such as inserting it into a Table Docking Station, before beginning the upgrade is highly recommended.
FIG. 104 Previous Firmware installation confirmation dialog box
FIG. 105 Upgrading from Previous Firmware System Message
If the MVP-9000i battery is at less than a 30 percent charge, the firmware upload will
automatically fail. For best results, before uploading the firmware, connect the panel
to its power source or place it in a Table or Wall Docking Station.

Table of Contents

Other manuals for AMX MVP-9000i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX MVP-9000i and is the answer not in the manual?

AMX MVP-9000i Specifications

General IconGeneral
BrandAMX
ModelMVP-9000i
CategoryTouch Panel
LanguageEnglish

Related product manuals