CCA Clear the calfactor value to zero.
CDJ Per form a CAL 0 dBm.
Re marks: Dur ing the cal 0 dBm se quence, the CAL ex e cu tion bit in the sta tus byte
is set. When the CAL op er a tion is com pleted, the CAL ex e cu tion bit is
cleared.
COF Clear the off set value to zero.
COS Turn ON the 50 MHz, 0 dBm RF cal i bra tor out put.
CRF Clear the ref er ence value to zero.
CST Turn OFF the 50 MHz, 0 dBm RF cal i bra tor out put.
DBM Sets the dis play chan nel units to dBm.
DBR Sets the dis play chan nel units to dB’s and takes the rel a -
tive value.
Re marks: The rel a tive value is stored as the ref er ence data. The ref er ence value
can be in de pend ently changed with the GPIB com mand REF.
EMUL GPIB em u la tion mode
Syn tax: EMUL <mode>
mode: ML24XX (Anritsu ML2400A Se ries na tive mode)
HP436A (Hewlett-Packard)
HP437B (Hewlett-Packard)
HP438A (Hewlett-Packard)
ML4803 (Anritsu ML4803A Se ries)
Re marks: Set the GPIB em u la tion to em u late other types of power me ters. This
com mand is avail able in any em u la tion mode, and re sets the whole
GPIB in ter face when the em u la tion mode is changed.
ML2400A OM 6-89
GPIB OPERATION ML4803A EMULATION COMMANDS

Table of Contents