E1 Analyzer (Option 50, S331D only)
Line Coding: AMI, HDB3
Framing Modes: PCM30, PCM30CRC, PCM31, PCM31CRC
Connection Configurations: Terminate (75W, 120W)
Bridge (³1000W)
Monitor (Connect via 20 dB pad in DSX)
Receiver Sensitivity: 0 to –43 dB
Clock Sources: External
Internal, 2.048 MHz ± 30 ppm
Pulse Shapes: Conform to ITU G.703
Pattern Generation and Detection:
PRBS: 2-9, 2-11, 2-15, 2-20, 2-23 Inverted and
non-inverted, QRSS, 1-in-8 (1-in-7), 2-in-8, 3-in-24,
All ones, All zeros, T1-Daly, User defined (£ 32 bits)
Circuit Status Reports: Carrier present, Frame ID and Sync., Pattern ID and Sync.
Alarm Detection: AIS, RAI, MMF
Error Detection: Frame Bits, Bit, BER, BPV, CRC, E-Bits, Error secretary
Error Insertion: Bit, BPV, Framing Bits, RAI, AIS
Loopback Modes: Self loopback
Level Measurements: Vp-p 5%), dBdsx
Data Log: Continuous, up to 48 hrs
FCN4760 Frequency Converter (for use with Option 6, S332D only)
Frequency Range 4.7 GHz to 6.0 GHz
Frequency Resolution* 10 Hz
Frequency Reference Aging: ± 1 ppm/yr
Accuracy: ± 2 ppm
SSB Phase Noise £–65 dBc/Hz
(6 GHz) @ 30 kHz Offset
Spurious Responses £–45 dBc
Input Related
Spurious Residual £–90 dBm
Responses*
Measurement Range –40 dBm to –100 dBm
Sensitivity* (displayed £–100 dBm
average noise level)
Accuracy ± 1.75 dBm typ. (± 2.25 dBm max.)*
Maximum Input Level –5 dBm
without damage
Input and Output Ports:
RF In Type N, female, 50W
RF Out Type N, male, 50W
Table 1-1. Performance Specifications (5 of 6)