CHAPTER 4
OPERATING INSTRUCTIONS
Entire Contents Copyright 2004 by Adaptive Power Systems, Inc. (APSI) • All Rights Reserved • No reproduction without written authorization from APSI.
APS-3000P Series 4 - 18 OM-001-03000-00P-03.9
Frequency
Display
Voltage
Display
Current
Display


/

High Current Limit. Press the CURRENT ︿ or buttons to select between OFF and 0.0
nn.nn, the units nominal current. When set to OFF, there is no current high limit. When
system is in RESET (Standby) status, pressing the CURRENT ︿ or buttons will adjust the
current high limit.
Frequency
Display
Voltage
Display
Current
Display


/

Lo Current Limit. Press the CURRENT ︿ or buttons to select between OFF and the
full range in multiples of 0.1. When set to OFF, there is no current low limit.
Frequency
Display
Voltage
Display
Current
Display


/

High Power Limit. Press the CURRENT ︿ or buttons to select between OFF and the
full range in multiples of 0.01 of the unit’s nominal power. When set to OFF, there is no power
high limit.
Frequency
Display
Voltage
Display
Current
Display


/

Lo Power Limit. Press the CURRENT ︿ or buttons to select between OFF and the full
range in multiples of 0.01 of the unit’s nominal power. When set to OFF, there is no power low
limit.
Frequency
Display
Voltage
Display
Current
Display


/

High Power Factor Limit. Press the CURRENT ︿ or buttons to select between OFF
and 0.001 1.000. When set to “OFF”, there is no power factor high limit.