CHAPTER 4
OPERATING INSTRUCTIONS
Entire Contents Copyright 2004 by Adaptive Power Systems, Inc. (APSI) • All Rights Reserved • No reproduction without written authorization from APSI.
APS-3000P Series 4 - 19 OM-001-03000-00P-03.9
Frequency
Display
Voltage
Display
Current
Display


/

Low Power Factor Limit. Press the CURRENT ︿ or buttons to select between OFF and
0.001 1.000. When set to OFF”, there is no power factor low limit.
Frequency
Display
Voltage
Display
Current
Display

S

/
Program Connect / Step. Press the CURRENT ︿ or buttons select between ON/OFF.
OFF There is no connection between program steps.
ON When the operations associated with a program step have been completed, the unit
will sequence directly to the next step of the (same) program group. For example, after
executing Program 1, Step 1, the system will begin execution of Program 1, Step 2, (P1-1
P1-2).
NOTE: To connect steps between program sets, the PROGRAM parameter AutoRUN
of the next program set must be set as ON. (For example, P1-5 → P2-1). With Program
Connect ON and AutoRUN ON for each program, all eight programs can be linked. This
provides the capability for up to 40 manually programmed steps to be sequentially
executed.