75
Check for axle
problem and if the
same model of motor
is available.
Replace parts one by
one to isolate the real
cause to the problem.
Replace the broken part.
Slow system
response
Check the power
supply.
Check if the output
voltage of power supply
is within the allowable
range.
Adjust the output voltage or
replace the power supply for
switch.
Check the system
parameters for any
error.
Suggest to record the original parameters before
making any modification.
Travel limit alarm
at power
-on
Check if any external
limit switch is
connected.
Check if limit switches
are functional and if
loose connection or
disconnection exists.
Secure the connection.
If no external limit switch is connected,
check the system if the current coordinate
values are too high and out of the travel limit
set by software. Check if the travel limit set by
software is too small.
Modify it to normal range.
In DIAGNOSE
window, trigger the
external limit switch.
Check for any change with the corresponding input
port.
No response to
keystroke or
wrong key
assignments
Check the cable for
keyboard.
Check if the keyboard is
loosely connected or
disconnected.
Secure the connection.
The system is
locked up in
manual/automatic
mode.
Incorrect parameter
setting.
Record the electronic gear in system parameters and
then press G, G and 3 in the system main window
successively. Save the parameters in parameter setting
mode. Restart the system and fill the recorded value of
electronic gear into the corresponding position. Save
the parameter and test the system performance.

Table of Contents