EasyManua.ls Logo

Aritech 2X Series User Manual

Aritech 2X Series
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
2X Series Installation
Manual
P/N 501-405003-1-31 • REV 03.10 • ISS 07NOV13

Table of Contents

Other manuals for Aritech 2X Series

Question and Answer IconNeed help?

Do you have a question about the Aritech 2X Series and is the answer not in the manual?

Aritech 2X Series Specifications

General IconGeneral
CertificationsEN54-2, EN54-4
Power Supply230V AC, 50Hz
Battery Capacity7Ah
Current ConsumptionStandby: 50mA
Humidity RangeUp to 95% RH, non-condensing

Summary

Important Information

Introduction

Overview of the manual's purpose and related documentation.

Firmware compatibility

Details control panel compatibility with firmware versions.

Limitation of liability

Legal disclaimer regarding product use and potential damages.

Advisory messages

Explains warning, caution, and note messages used in the document.

Chapter 1 Introduction

Product range

Lists the available fire alarm, repeater, and evacuation panel models.

Repeater functionality

Explains network configuration for repeater panels.

Fire routing and fire protection control and indication

Applies to panels with specific fire control features.

Product compatibility

Lists compatible products and ensures system compatibility.

Product overview

Introduces panel interface, controls, and indicators.

The user interface

Describes the layout of the control panel interface.

Evacuation panel controls and indicators

Details additional controls for evacuation panels.

Configuration options

Describes options that may change interface button labels.

Front panel controls and indicators

Explains operational features of front panel controls.

Common controls and indicators

Information on shared controls and indicators across panel types.

Icons displayed on the LCD

Explains the meaning of icons shown on the control panel's LCD.

Indication of remote and local events on the LCD

Describes how network and local events are displayed.

Acoustic indicators

Explains the function of the control panel buzzer.

Conditions

Summarizes system events logged as conditions.

Chapter 2 Installation

Electrical safety

Crucial safety precautions for electrical hazards during installation.

Cabinet and PCB layout

Details the physical layout of the control panel and its internal components.

Cabinet installation

Instructions on mounting the control panel cabinet.

Adding the menu inserts

Guidance on inserting custom panel interface labels.

Connecting the user interface cable

Step-by-step guide for connecting the UI cable.

Connecting the internal printer and loading paper

Procedures for printer setup and paper loading.

Connections

Information on recommended cables and connection practices.

Overview of fire system connections

Illustrates typical wiring diagrams for fire systems.

Connecting loops

Guidelines for connecting loop devices and system wiring.

Connecting loop devices

Details for connecting individual devices to the loops.

Connecting inputs

Instructions for wiring and configuring control panel inputs.

Connecting outputs

Instructions for wiring and configuring control panel outputs.

Connecting the mains power supply

Essential procedures and safety for power connection.

Connecting the batteries

Guidance on installing and connecting the panel batteries.

Connecting expansion boards

Instructions for adding expansion modules.

Connecting a fire network

Steps to link multiple panels into a network.

Connecting an external printer or ASCII terminal

How to connect external devices for data output.

Chapter 3 Configuration and commissioning

User levels

Explains different access levels and their permissions.

Configuration overview

Overview of PC-based configuration methods.

Maintenance level operation and configuration

Tasks and settings available for maintenance users.

The Panel setup menu

Panel configuration for date, time, and modes.

The Communications menu

Setup for email notifications and USB device management.

The Disable/Enable menu

How to enable or disable system features and devices.

The Test menu

Procedures for testing various system functions and devices.

Locating devices

How to identify device location using LED activation.

Service mode

Activates mode to prevent accidental output changes during tests.

The Reports menu

Accessing logs, revisions, and status reports.

The Password setup menu

Managing user passwords and accounts.

Installer level operation and configuration

Comprehensive configuration for installers.

Panel configuration

Settings for panel ID, description, network, and communications.

ID configuration

Setting the control panel's Firenet ID and description.

Regional options

Setting the panel's regional operating mode.

Firenet configuration

Configuring the fire network topology and operation.

Communications configuration

TCP/IP, email server, and other communication settings.

Other settings

Configuration for auxiliary outputs, fault masks, and sounder behavior.

Expansion board configuration

Adding and configuring installed expansion boards.

Load auxiliary files

Loading custom screens, languages, or fonts.

Firmware updates

Procedures for updating the control panel firmware.

Printer configuration

Settings for internal and external printers.

DACT configuration

Configuration for the DACT expansion board.

Field configuration

Configuring devices, zones, and I/O parameters.

Autosetup

Automatically configures installed loop devices.

Loop device configuration

Manually configuring loop devices.

Zone configuration

Configuring zone settings like type, area, and delays.

Area configuration

Setting up confirmation areas for zones.

Panel I/O configuration

Configuring control panel inputs and outputs.

Output groups

Configuring output groups for activation and status.

Activation configuration

Setting delays for output groups and sounder behavior.

Loop Class configuration

Configuring the loop wiring class (A or B).

Tests

Tools for troubleshooting and diagnostics.

Diagnostics

Running tests for device diagnostics, output current, power supply, and loop values.

Password setup

Managing user passwords and access levels.

Commissioning

Final checks and procedures before system operation.

Chapter 4 Maintenance

Fire alarm system maintenance

Procedures for system inspections and cleaning.

Battery maintenance

Information on battery care, faults, and replacement.

Chapter 5 Technical specifications

Loop specifications

Technical details on loop configuration and devices.

Power supply specifications

Electrical parameters for the power supply unit.

Battery and battery charger specifications

Technical details for batteries and charging system.

LCD specifications

Technical details of the LCD display.

Communication port specifications

Specifications for Ethernet, TCP/IP, and USB ports.

Fire network specifications

Technical details on network connectivity.

Input and output specifications

Technical data for panel inputs and outputs.

Internal printer specifications

Technical details of the internal printer.

Mechanical and environmental specifications

Physical dimensions, weight, IP rating, and operating environment.

Appendix A Default configurations

Default configurations

Lists the panel's default configuration settings.

Appendix B PSTN country codes

PSTN country codes

Reference list of country codes for PSTN configuration.

Appendix C Menu maps

Fire alarm control panels

Menu structure for fire alarm panels.

Fire alarm repeater panels

Menu structure for repeater panels.

Appendix D Regulatory information

European regulations for construction products

Regulatory information for construction products.

European standards for electrical safety and electromagnetic compatibility

Compliance with electrical safety and EMC standards.

Related product manuals