Chapter 2 INDIVIDUAL FORMATS FOR VG CONTROL COMMANDS
291
2.175 EXECON4 [24H 4CH] : Output Terminal Setting
Function : this command sets ON/OFF of each output terminal.
Sequence : Type 2
Command:
STX
1 BYTE
02H
VG4CMD
1 BYTE
FDH
EXCON4
2 BYTE
24H 4CH
Output Terminal Code#1
1-3 BYTE
"0"-"999"
,
1 BYTE
2CH (Delimiter)
Output Terminal Information
#1
1-3 BYTE
"0"=OFF, "1"=ON
,
1 BYTE
2CH (Delimiter)
Output Terminal Code#2
1-3 BYTE
"0"-"999"
,
1 BYTE
2CH (Delimiter)
Output Terminal Information
#2
1 BYTE
"0"=OFF, "1"=ON
,
1 BYTE
2CH (Delimiter)
,
1 BYTE
2CH (Delimiter)
Output Terminal Code#N
1-3 BYTE
"0"-"999"
,
1 BYTE
2CH (Delimiter)
Output Terminal Information
#N
1 BYTE
"0"=OFF, "1"=ON
ETX
1 BYTE
03H
Fig. 0-1
* About output terminal code, refer to Fig.2-132-2 for VG-870, 871 and 880. Refer to Fig. 2-132-3 for VG-882
and VG-883. Refer to Fig. 2-132-4 for VG-884. Refer to Fig.2-132-5 for VG-876.
* If the output terminal code that does not exist in VG, it is ignored.
PC
VG
STX-ETX
ACK or
STX+ESTS+Error Code+ETX

Table of Contents