Trouble on One Voice Terminal
Step 14.
Check the modular jack(s) to make sure there are no broken wires, that
the wires are tightly inserted in their notches, that wires are not touching
each other, and that the wires are inserted in the correct order. See Fig-
ure 21.
IF
THEN
The wiring is OK and a jack panel
The trouble is not caused by the
is NOT used to connect the voice
wiring. Replace the plastic caps by
terminal to the control unit,
aligning them and applying pres-
sure until they snap into place.
Replace the jack cover and tighten
the screw. Call your equipment
supplier for help.
The wiring is OK and a jack panel
Trouble found.
It is caused by
is used to connect the voice termi-
the
modular to modular connector
nal to the control unit,
in the jack panel that is connected
to the voice terminal with trouble.
Replace the plastic caps by align-
ing them and applying pressure
until they snap into place.
Read the section on Maintenance
Exchange Procedures at the end of
this manual.
There is a problem with the wir-
Trouble found.
It is caused by
ing,
the
wiring.
Read the section on Maintenance
Exchange Procedures at the end of
this manual.
Page 47