Check the display (2) regularly for readings and messages. The display normally shows the compressor
outlet pressure, while the status of the compressor is indicated by pictographs. Remedy the trouble if alarm
LED (7) is lit or flashes, see section Shutdown warning, Shutdown and Problem solving. The display (2)
will show a service message if a service plan interval has been exceeded or if a service level for a
monitored component has been exceeded. Carry out the service actions of the indicated plans or replace the
component and reset the relevant timer, see section Service warning.
Compressors with Elektronikon® Graphic controller:
Control panel Elektronikon® Graphic
Check the display (2) regularly for readings and messages. The display normally shows the compressor
outlet pressure, while the status of the compressor is indicated by means of a number of icons. Remedy the
trouble if alarm LED (7) is lit or flashes, see section Icons used. The display (2) will show a service
message if a service plan interval has been exceeded or if a service level for a monitored component has
been exceeded. Carry out the service actions of the indicated plans or replace the component and reset the
relevant timer, see section Service menu.
7.6 Stopping
Control panel Elektronikon®
Instruction book