Special protections
Lists all special protections of the unit.
Service plan
Displays all levels of the service plan and their status. This screen shot underneath only shows the running
hours. It is also possible to show the current status of the service interval.
3.33 Programmable settings
Parameters: unloading/loading pressures for compressors without built-in refrigeration dryer
Minimum
setting
Factory
setting
Maximum
setting
Unloading pressures
Unloading pressure (7.5 bar compressors) bar(e) 4.1 7 7.5
Unloading pressure (7.5 bar compressors) psig 59.5 101.5 108.8
Unloading pressure (8.5 bar compressors) bar(e) 4.1 8 8.5
Unloading pressure (8.5 bar compressors) psig 59.5 116 123.5
Unloading pressure (10 bar compressors) bar(e) 4.1 9.5 10
Unloading pressure (10 bar compressors) psig 59.5 137.8 145.0
Unloading pressure (13 bar compressors) bar(e) 4.1 12.5 13
Unloading pressure (13 bar compressors) psig 59.5 181.3 188.6
Unloading pressure (100 psi compressors) bar(e) 4.1 6.9 7.4
Instruction book
2920 7180 30 65