2.3 Cooling system
Diagram
Reference Description
1 Intake air
2 Air/oil mixture
3 Oil
4 Wet compressed air
5 Condensate
Description
The cooling system on air-cooled compressors comprises air cooler (Ca) and oil cooler (Co).
The cooling air flow is generated by fan (FN).
2.4 Condensate system
The condensate, collected in the moisture trap of the air cooler, is evacuated via an automatic drain. A
compressor with integrated dryer has an additional drain on the moisture trap of the dryer. Each drain is
connected to its outlet connection (Da) and a manual drain valve (Dm).
Mechanical drains
GA 37 and GA 45 have a mechanical condensate drain (MWD).