Control panel Elektronikon® Graphic
Procedure
Step Action
1 Press stop button (9). Automatic operation LED (8) goes out and the compressor stops after
30 seconds of unloaded operation.
2 To stop the compressor in the event of an emergency, press emergency stop button (10).
Alarm LED flashes (7).
On compressors equipped with an Elektronikon® controller, remedy the problem cause,
unlock the button by pulling it out and press the Escape button (5) to reset.
On compressors equipped with an Elektronikon® Graphic controller, remedy the problem
cause and unlock the button by pulling it out.
Navigate to the Stop icon on the display by means of the navigation keys (3/4) and press
the Select key.
Press Reset.
Do not use emergency stop button (10) for normal stopping!
3 Close the air outlet valve.
4 Press the test button on top of the electronic water drain(s) (if supplied) to the depressurize the
piping between air receiver and outlet valve, next open the manual drain valve (Dm). See
section Condensate system.
Switch off the voltage.
7.7 Taking out of operation
Warning
The operator must apply all relevant Safety precautions.
Procedure
Step Action
- Stop the compressor and close the air outlet valve.
Instruction book
2920 7180 30 149