EasyManua.ls Logo

Atlas Copco GA 30+ - Technical Data Controller

Atlas Copco GA 30+
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.5 bar 8.5 bar 10 bar 13 bar 100 psi 125 psi 150 psi 175 psi
Dryer power at no load,
units with integrated
dryer
kW 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4
Dryer power at no load,
units with integrated
dryer
hp 1.6 1.6 1.6 1.6 1.9 1.9 1.9 1.9
Refrigerant type, units
with integrated dryer
R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant quantity,
units with integrated
dryer
kg 1 0.8 0.8 0.8 1 0.9 0.9 0.9
Refrigerant quantity,
units with integrated
dryer
lb 2.1 1.8 1.8 1.8 2.2 1.9 1.9 1.9
Oil capacity l 17.7 17.7 17.7 17.7 17.7 17.7 17.7 17.7
Oil capacity US gal 4.12 4.12 4.12 4.12 4.12 4.12 4.12 4.12
Sound pressure level
(according to ISO 2151
(2004))
dB(A) 67 67 67 67 67 67 67 67
GA 45
7.5 bar 8.5 bar 10 bar 13 bar 100 psi 125 psi 150 psi 175 psi
Frequency Hz 50 50 50 50 60 60 60 60
Maximum (unloading)
pressure
bar(e) 7.5 8.5 10 13 7.4 9.1 10.8 12.5
Maximum (unloading)
pressure
psig 109 123 145 189 107 132 157 181
Maximum (unloading)
pressure, units with
integrated dryer
bar(e) 7.3 8.3 9.8 12.8 7.2 8.9 10.6 12.3
Maximum (unloading)
pressure, units with
integrated dryer
psig 106 120 142 186 104 129 154 178
Reference working
pressure
bar(e) 7 8 9.5 12.5 6.9 8.6 10.3 12
Reference working
pressure
psig 102 116 138 181 100 125 150 175
Pressure drop over
dryer, units with
integrated dryer
bar(e) 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
Pressure drop over
dryer, units with
integrated dryer
psig 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6
Set point of thermostatic
valve
˚C 40 40 40 60 40 40 40 60
Set point of thermostatic
valve
˚F 104 104 104 140 104 104 104 140
Instruction book
178 2920 7180 30

Table of Contents

Related product manuals