CHAPTER5 Cabling the Device
Mediant 1000 Gateway & E-SBC | Hardware Installation Manual
Make sure that FXO ports are connected to the appropriate external devices;
otherwise, damage to the device may occur.
FXO ports are considered as ES2 (Energy Source class 2).
(French) Avertissements:
Pour vous protéger contre l’électrocution et le feu, utilisez un fil de 26 AWG au
minimum pour connecter le port FXO au PSTN.
Assurez-vous que le port FXO soit connecté à un appareil externe approprié ;
autrement, vous risquez d’endommager l’appareil.
Le port FXO est considéré être un ES2.
The FXO module is a separate orderable item. This section is applicable only if your
device is installed with such a module.
Indoor FXO Cabling
The following procedure describes how to cable FXO ports for indoor routing.
Cabling specifications:
Cable: Standard straight-through RJ-11-to-RJ-11 telephone cable
Connector: RJ-11
Connector Pinouts:
Figure 5-9: RJ-11 Connector Pinouts for FXO
To connect FXO interfaces for indoor routing:
1. Connect one end of the straight-through RJ-11 cable to the RJ-11 port on the FXO module.
2. Connect the other end of the cable to an RJ-11 telephone wall outlet or PBX.
Outdoor FXO Cabling
The following procedure describes how to cable FXO ports for outdoor routing.
The device must be installed only in telecommunication sites / centers in
compliance with ETS 300-253 requirements “Earthing and Bonding of
Telecommunication Equipment in Telecommunication Centers”.
- 41 -

Table of Contents

Other manuals for AudioCodes Mediant 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 1000 and is the answer not in the manual?

AudioCodes Mediant 1000 Specifications

General IconGeneral
Data link protocolsCAS: MF-R1: T1 CAS, ISDN PRI: ETSI/EURO ISDN, ANSI NI2, QSIG
Security algorithmsHTTPS, SRTP
Authentication methodRADIUS
Internal memory512 MB
Built-in processorCeleron 600 MHz
Processor frequency600 MHz
Internal memory type-
Number of processors installed1
Voice codecsG.711, G.723.1, G.726, G.729A, iLBC
SafetyUL60950-1, FCC 47 CFR
CertificationETS 300019-2-1, ETS 300019-2-2 ETS 300019-2-3
Mounting typeRack mounting
LED indicatorsYes
Power requirements90-260 V AC
Weight and Dimensions IconWeight and Dimensions
Size (imperial)19 \

Related product manuals