AUTOFRY Models FFG-10 and MTI-10 Operator's Manual
Safety System Test (cont.)
The AUTOFRYis equipped with an airflow switch. To test this switch follow these
instructions.
1. With all the filter components installed and the main door closed press the
ON button at the keypad.
2. Using a flat piece of cardboard or 1/4" plywood completely block the exhaust
flow at the fire damper / stack cover.
The fan will begin to operate.
It can take upwards of 45 minutes for the air flow switch to react to the
blockage; However, after the air switch has closed, the display will either go
blank or display Sft.
If the oil has heated above 151° F the fan will continue to operate until it cools to
120° F.
Included with this manual is a maintenance log that must be signed and dated
after the completion of the daily, weekly and quarterly maintenance and testing.
Your local or State health and safety inspectors may require this log to be posted in
a conspicuous location.
MTI FormOP-0010 Rev. 005 5/98