6 System Screen
54 © Copyright Reserved Autonics Co., Ltd.
(3) CH1/CH2 details configuration
No. Function and operation
Touch this, detailed configuration screen for designated operation mode appears.
Designate operation mode.
CH1,2 protocol: Communication mode for set PLC by LP and GP Editor by each
port.
EDITOR: I/O mode for downloading user-designed data from GP Editor
PRINTER: Print mode for printing alarm history of LP
(For more details, refer to GP LP user manual for communication’)
BARCODE: Input mode for reading data from barcode.
(For more details, refer to GP LP user manual for communication’)
MONITOR: Available only in CH2. Monitoring mode for PLC which is connected
to LP from PC directly. LP is as transmitter by transmitting data from PC to PLC
and data from PLC to PC. In case of MITSUBISHI FX-Series, editor mode is
available for monitoring.
NoUse: Displayed only not using appropriate CH.
Designate baud rate.
Supports 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Data: Designate data bit
Supports 7 bit, 8 bit.
Parity: Designate parity type.
Supports even, odd, or none parity.
Stop bit: Designate stop bit.
Supports 1 bit, or 2 bit.
Flow control: Designate data flow control.
Supports XON/ XOFF, or DSR/DTR.