EasyManua.ls Logo

Avaya CMC1 - Place Test Call; Troubleshooting

Avaya CMC1
370 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Adding or Removing Hardware
322 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
7. Set the Signaling Mode: field to isdn-pri
8. Set the Connect: field to pbx
9. Set the Interface: field to network
10. Set the Country Protocol:field to 1
11. Set the Protocol Version:field to a
12. Set the CRC?:field to y
13. The Idle Code default is 11111111.
14. The DCP/Analog Bearer Capability default is 3.1 kHz.
15. Set the MMI Cabling Board: field to xxxxx (where xxxxx is the location of the TN787F/
H/J/K MMI circuit pack recorded in step 2). This must be the slot for port B of the Y-cable.
16. The MMI Interface: field ESM appears.
17. Enter add signaling-group next and the signaling-group form appears.
18. Change Associated Signaling: field to y.
19. Change Primary D-Channel Port: field to xxxx17 (where xxxx is the address of the
TN2207 PRI circuit pack, for example: 1B0517).
20. The Max Number of NCA TSC: default is 0.
21. The Max Number of GA TSC: default is 0.
22. Trunk Group for NCA TSC: ____ (leave blank)
23. Trunk Group for Channel Selection:____ (leave blank)
24. Logoff the terminal and then log back on the terminal to view your changes.
Place test call
Place multimedia data-conference call to an endpoint with known video capability to test the
esm function.
Troubleshooting
To determine ESM link status enter the following commands from the system administration
terminal:
1.Status esm
2.Status signaling-group
3.List MMI

Table of Contents