340 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
PRI-to-BRI converter
Figure 108 shows typical connections from the PRI-to-BRI converter to the coaxial facility.
Figure 108: Typical PRI to BRI converter cabling
Note:
Note: The inset shows details of the cable connections between the circuit packs.
Connect the Communication Manager administration PC to the RS-232
connector on the front of the PRI converter circuit pack.
Figure notes:
1. To TN464GP DS1 circuit pack and
PRI-to-BRI converter circuit pack
2. Communication Manager administration PC
3. RS-232 cable to front of converter circuit
pack
4. 888B coaxial converter
5. Coaxial connection to 2-Mbps facility
6. Coaxial cable from PRI converter
circuit pack to coaxial converter
7. TN464GP circuit pack
8. PRI-to-BRI converter circuit pack
9. Jumper coaxial cable
10. Inset showing connections on rear
of carrier
0007_0 RBP 051396
7
(2B+D)
1
(2B+D)
8
(2B+D)

Table of Contents