.Install ISDN converters and adapters
Issue 10 June 2005 339
Converters for single-carrier cabinets
PRI-to-DASS and PRI-to-DPNSS converters
Figure 107 shows typical connections from the CCSC-1 PRI-to-DASS converter or the CCSC-2
PRI-to-DPNSS converters to the coaxial facility.
Figure 107: Typical DASS or DPNSS converter cabling
1. Plug the PC into the RS-232 connector on the front of the PRI converter circuit pack.
2. Connect the coaxial Y-cable from the TN464GP to the PRI converter circuit pack.
3. Connect the opposite end of the Y-cable to the 888B coaxial converter.
Figure notes:
1. To TN464GP DS1 circuit pack and either a
CSCC-1 PRI-to-DASS converter or a CSCC-2
PRI-to-DPNSS converter circuit pack
2. Communication Manager administration PC
3. RS-232 cable to front of PRI converter circuit
pack
4. 888B coaxial converter
5. Coaxial connection to
2-Mbps facility
6. Coaxial cable from PRI
converter circuit pack to
coaxial converter