the DAP IP Range exclusive for DAPs only is selected
the Subnet Mask is entered
the Default gateway is entered
the TFTP IP address (of the DAP Controller PC) is entered
the DHCP Server is running (Activate / Deactivate / System status button)
If you use built-in TFTP Server (IP DECT Configurator), ensure
Run TFTP Server on this PC is selected
3com TFTP Server on this PC is selected
TFTP Server is running (Activate / Deactivate / System status button)
For more information, see DHCP and TFTP servers on page 76.
If you cannot make calls to or from a DECT Handset with SIPL
configuration
Perform the following steps if you cannot make calls.
1.
Ensure that the SIP Line Gateway, Call Server, and DECT system are configured
and connected to the Ethernet.
2. Ensure that the DAPs are working.
3. Verify that a dial tone sounds if a handset goes off-hook. If no dial tone sounds, the
SIP DECT Handset is not registered on SIP Line Gateway. Verify that the following
SIP settings are configured properly:
For IP DECT Configurator:
- ensure that the following values are configured:
Proxy IP address = SIP Line Gateway node IP address
Proxy IP address port = SIP Line Gateway node IP address port
For more information, see
Configuring IP Settings on page
95.
- ensure that the following values are configured: SIP domain = root domain
(SIP Line configuration)
Realm = SIP domain (case-sensitive)
user and password are entered correctly
use_registrar = yes
redirect=no
multiple_sip_ports=yes
System maintenance