Field Name Description
be the same as the one used by Scopia
®
Management.
Gatekeeper Service Prefix This is an optional field. Enter the service prefix
designator for this conference point. You can
leave this field as blank.
6. Click Save.
Specifying polling intervals and the network address
About this task
You must specify how frequently the Scopia
®
SR communicates with the other components, such as
the conference points and delivery nodes. You must also specify the network on which the Scopia
®
SR resides. The polling interval should be in proportion to the number of devices. The fewer the
devices, the shorter the intervals. For example, if you have over 200 delivery nodes, Avaya
recommends setting the polling to 5 minutes.
The polling frequency affects the latency between the status transitions of the remote device and the
appearance of the status on the details page for the device.
Procedure
1. Log in to Scopia
®
SR.
2. Click the Global Policies tab.
3. Click General Options.
4. Configure the settings, as described in Table 8: Polling Settings on page 41.
Table 8: Polling Settings
Field Name Description
Conference Point Polling Frequency Specify how often the Scopia
®
SR Manager
checks for device configuration or status
changes for each of the conference points.
Delivery Node Polling Frequency Specify how often the Scopia
®
SR Manager
checks for device configuration or status
changes for each of the delivery nodes.
Network Address for Device Communication Enter the IP address or the DNS address that
the Scopia
®
SR Manager should use to access
the devices in the system.
5. Click Save.
Specifying polling intervals and the network address
June 2015 Installing the Avaya Scopia
®
Streaming and Recording Server 41
Comments on this document? infodev@avaya.com