12/14 Rev. 03 USER MANUAL Commissioning & Operation
64-xx
18
SD card:
1. Switch off the printer. Wait for 5 seconds.
2. Press onto the memory card, until it unlocks. Remove the memory card from
the card slot.
[14] Inserting a memory card (A: CF, B: SD). If the memory card has been inserted correctly,
it will sit flush with the printer’s back wall (right).
Setting the realtime clock
The realtime clock in the 64-xx printers can be used, for example, to calcu-
late and print the expiry date of a perishable product.
This is how you set the realtime clock:
1. Navigate to the
SYSTEM PARAMETER > Realtime Clock.
2. To enter the date and time, use the Cut button to shift the cursor, the Feed
button to change the parameter, and the Online button to save it.
Setting parameters: see topic section „Info-Printouts and Parameters“,
chapter “Using the Parameter Menu”.
Outputting the realtime clock value using Easy Plug
Use the following Easy Plug commands to output the current realtime clock
value:
#YC realtime as text
#YS realtime as barcode
#DM download month names
Easy Plug manual
Realtime clock
dd.mm.yyyy hh:mm
dd = day, mm = month, yyyy = year, hh = hour,
mm = minute
A